Top 9 Run Capacitor Ge 97F9003

0
688 reviews analysed

1. 97F9003 – 12.5 uf MFD 370 Volt VAC – GE Oval Run Capacitor Upgrade

97F9003 - 12.5 uf MFD 370 Volt VAC - GE Oval Run Capacitor Upgrade

Feature

2. PowerWell 40 + 5 MFD uf 370 VAC or 440 Volt Dual Run Round Capacitor PW-40/5/R for Condenser Straight Cool or Heat Pump Air Conditioner 40/5 Micro Farad – Guaranteed to Last 5 Years

PowerWell 40 + 5 MFD uf 370 VAC or 440 Volt Dual Run Round Capacitor PW-40/5/R for Condenser Straight Cool or Heat Pump Air Conditioner 40/5 Micro Farad - Guaranteed to Last 5 Years

Feature

3. PowerWell 60+7.5 uf MFD 370 or 440 Volt Dual Run Round Capacitor PW-60/7.5R Condenser Straight Cool/Heat Pump Air Conditioner

PowerWell 60+7.5 uf MFD 370 or 440 Volt Dual Run Round Capacitor PW-60/7.5R Condenser Straight Cool/Heat Pump Air Conditioner

Feature

Description

A capacitor is an electric component that temporarily stores an electrical charge. A dual “run capacitor” supports two electric motors, such as in large air conditioner or heat pump units, with both a fan motor and a compressor motor. It saves space by combining two physical capacitors into one case. The dual capacitor has three terminals labeled “C”, “FAN”, and “HERM”, which stand for the *C*ommon, Fan, and *HERM*etically sealed compressor.

Dual capacitors come in a variety of sizes, depending on the capacitance (µF or MFD), such as 40 plus 5 µF, and also the voltage. A 440 volt capacitor can be used in place of a 370 volt, as it is build better, but the 370 can’t be used in place of a 440 volt. It will work for a while and will fail prematurely, as exceeding the capacitor’s rated voltage will cause the dielectric to break down and the capacitor to short out. Same as an electric wire- 600V rated wire is better than 300V one .The capacitance(µF or MFD) must be the same or stay within +10% or -10% of its original value . Example: 50 µF cap can be substituted by 45 to 55 µF with the same or better voltage ratings capacitor .

Round cylinder-shaped dual run capacitors are commonly used for air conditioning, to help in the starting of the compressor and the condenser fan motor.Round capacitor can be used to substitute oval shape one with the same MFD AND Volt specs

You will ask “Why I need a Cap that is rated 440V in my A/C?”

Answer: You need to realize that a motor is an inductive device. When the supply voltage is applied to the motor run winding, the voltage across the start winding will be increased to a higher voltage value. A motor acts like a transformer with the run winding acting as the primary and the start winding acting as the secondary. This is why the capacitor has a much higher voltage rating than the 230 being the supply voltage.

If a Capacitor is not EIA-456-A approved means it is not approved for US market.

4. Motor Run Capacitor, 12.5 MFD, 2-7/8 in. H

Motor Run Capacitor, 12.5 MFD, 2-7/8 in. H

Feature

Description

Motor Run Capacitor, 12.5 Microfarad Rating, 370-440V Voltage, 60/50 Hz, Round Shape, 1-3/4 In. Diameter, 2-3/8 In. Case Height, 2-7/8 In. Overall Height, 1-3/4 In. Overall Width, 1-3/4 In. Overall Depth, EIA UL Base P, Terminal Type 1/4 In. Male Quick-Connect, -40 Degrees to 70 Degrees C Temp. Range, Case Material Aluminum, Cover Material Steel, Standards UL Recognized (E185318)

5. 97F5459-12.5 uf MFD 370 Volt VAC – GE Oval Run Capacitor Upgrade

97F5459-12.5 uf MFD 370 Volt VAC - GE Oval Run Capacitor Upgrade

Feature

Description

This is a Brand New OEM GE/Genteq capacitor. GE/Genetq capacitors are top of the line capacitors, made in North America. GE/Genteq capacitors are used in a large variety of OEM applications.

6. BOJACK Motor and Fan Starting Round Capacitor 30 uf MFD 370V 450VAC 50/60Hz CBB65 10000AFC

BOJACK Motor and Fan Starting Round Capacitor 30 uf MFD 370V 450VAC 50/60Hz CBB65 10000AFC

Feature

Description

This capacitor is used for start-up and operation of AC motors with frequency of 50Hz/60Hz such as air conditioners, compressors and motors. It is small in size, lightweight, heat resisting and anti-explosion.

Round capacitor can be used to substitute oval shape one with the same MFD AND Volt specs.

A 440 volt capacitor can be used in place of a 370 volt, as it is build better, but the 370 can’t be used in place of a 440 volt.

Model: CBB65(Universal model)
Shell material: metal
Dielectric Material: metallized polypropylene film
Capacity: 30uf
Tolerance: ±5%
Rated voltage: 450V AC
Frequency: 50 / 60Hz

7. 2-Pack 12.5 MFD 370 Volt Oval Run Capacitor Replacement for GE 97F9003BX – CAP-97F9003, UpStart Components Brand

2-Pack 12.5 MFD 370 Volt Oval Run Capacitor Replacement for GE 97F9003BX - CAP-97F9003, UpStart Components Brand

Feature

Description

2-Pack Replacement 12.5 MFD 370 Volt Oval Run Capacitor for GE 97F9003BX – CAP-97F9003, UpStart Components Brand

8. BOJACK 70+5uF 70/5MFD ±5% 370V/440V CBB65 Dual Run Circular Start Capacitor for AC Motor Run or Fan Start or Condenser Straight Cool or Heat Pump air Conditioner

BOJACK 70+5uF 70/5MFD ±5% 370V/440V CBB65 Dual Run Circular Start Capacitor for AC Motor Run or Fan Start or Condenser Straight Cool or Heat Pump air Conditioner

Feature

Description

BOJACK Dual run circular start capacitor

ombines two capacitors into one unit. Three terminals on the top are labeled “Herm”/”H” for the compressor motor, “Fan”/”F” for the fan, and “C” for the common line.It will power a compressor motor and a fan motor

Model: CBB65(Universal model)
Shell material: metal
Dielectric Material: metallized polypropylene film
Capacity: 70+5uf
Tolerance: ±5%
Rated voltage: 440V AC
Frequency: 50 / 60Hz
Safety rated: 10,000 AFC
Capacitor dimension:Diameter<1.97 inch=""> Height <5.31 inch="">
Operating temperature: -40 ℃ to +70℃/-104℉to+158℉

This capacitor is used for start-up and operation of AC motors with
frequency of 50Hz/60Hz such as Industrial Grade Replacement for
Central Air-Conditioners, Heat Pumps, Condenser Fan Motors, and
Compressors.It is small in size, lightweight, heat resisting and anti-explosion.
Round capacitor can be used to substitute oval shape one with the
same MFD AND Volt specs.A 440 volt capacitor can be used in place
of a 370 volt, as it is build better, but the 370 can’t be used in place
of a 440 volt.

9. B9457-5500 – 40 + 5 uf MFD 370 Volt VAC – Goodman Round Dual Run Capacitor Upgrade

B9457-5500 - 40 + 5 uf MFD 370 Volt VAC - Goodman Round Dual Run Capacitor Upgrade

Feature

Description

This is a Brand New OEM GE/Genteq capacitor. GE/Genetq capacitors are top of the line capacitors, made in North America. GE/Genteq capacitors are used in a large variety of OEM applications.

Conclusion

By our suggestions above, we hope that you can found Run Capacitor Ge 97F9003 for you.Please don’t forget to share your experience by comment in this post. Thank you!

Home Previews
Logo
Enable registration in settings - general